Ensure the Safety of Building Occupants with an Automatic Fire Sprinkler System and Automated Heat Load Calculation Software
Building services software allows for the optimization of a building’s systems, including fire sprinklers, HVAC systems, heat load and lighting. The computer programs make it easy to manage a building’s systems and its health with centralized access. The software provides multiple benefits building management staff, such as higher energy efficiency, greater occupant comfort and productivity, and lower operating and maintenance costs.
The software provides for
higher energy efficiency with controllers and economizers for free cooling and maintaining
ventilation at the most efficient flow rates. Controllers, based on sensor
input, provide for optimized zone ventilation, heating, and air conditioning.
Controllers in many automatic firesprinkler systems provide smoke control during a fire, maintaining
breathable air zones for evacuation in the event of a fire. Modern building
services automation technology is cloud-based, so you can access most building
services programs from anywhere. This means you receive real-time software
updates or your automatic sprinklersystems, air conditioning, sound system, piping system for air
conditioning, heat load calculation
and other system software’ss.
SPRINK2000
The automatic fire sprinkler
system SPRINK2000 is capable of analysing looped and gridded systems, and
conventional tree configurations.
The computer program can be
used to carry out an analysis of hydrant systems with or without hoses or hose
reels.
· · The automatic sprinkler system uses the Hazen-William formula for hydrant analysis, and works for Metric, US, and British units.
· · All nodes that are not nominated as discharges or input points in SPRINK2000 automatic fire sprinkler system are automatically assigned as reference nodes to save user input.
· Booster pumps and backflow preventers can be included in the program and check valves can be made to restrict flow to one direction.
·
SPRINK2000 automatic fire sprinkler system
can be used to determine the design point, given the K-factor and minimum
discharge of each sprinkler head or hose reel.
·
A graphical display of the grid is provided
where the user can display pipe numbers, node numbers and pipe diameters or
lengths.
HYENA+
for hydraulic analysis of fire sprinkler and hydrant systems
The automatic sprinkler
system HYENA+ can perform a complete hydraulic analysis determining the water
flow in pressure drop through each pipe in the entered network. I
It can be used to carry out
a sprinkler system analysis in accordance with NFPA, NZ4541, AS2118 and SSPC52
specifications.
· · The piping system can have up to 10 input points for fixed pressure, a town mains water supply, or a pump.
·
Calculations
by HYENA+ use a process of matrix inversion to solve the differential
equations for each loop in the system.
· Piping materials for a wide range of codes are catered by HYENA+ automatic sprinkler system including steel, iron, and copper to Australian and New Zealand standards.
·
The computer program determines the actual I.
D. for different pipe materials when the pipe sizes are entered as nominal
sizes.
·
A wide range of fittings is provided for with
equivalent lengths stored in the program.
·
Booster pumps with backflow preventers can be
located anywhere in the network.
CAMEL
air conditioning load estimation and psychometrics analysis software
CAMEL computer program by
ACADS-BSG provides heat load calculation and psychometrics analysis and
operates in the Southern and Northern Hemispheres.
The computer program models
a range of system types including constant volume heating and cooling, VAV with
or without reheat, reverse cycle heat pumps, and evaporative coolers.
·
Each AHU of CAMEL heat load calculation
software serves a number of zones and rooms.
·
The program caters for overhangs complete
with drop panels that can be opaque or partially or completely transparent.
·
The comprehensive set of results provided by
CAMEL heat load calculation software include a summary table of loads and air
quantities, load charts, and tables of check figures.
·
Fresh air quantities can be entered at room
or zone level as I/s/person with plant fresh air quantities using the
Compartment Formula.
·
The results of CAMEL can also be displayed graphically,
and a psychometrics chart is provided for AHU.
·
The heat load calculation software CAMEL
calculates chiller, AHU, zone, and room loads and air quantities, and reheat
quantities with or without coil reset and room temperatures.